Description: R-2583 - MADISON COUNTY

Location: Bridge #328 over French Broad River.

Item(s) of Interest: Box Beams with unusual hold-down details. Currently preparing to pour a concrete overlay with glass fiber reinforced polymer (GFRP) rebar. An unusual end bent with crash wall on sheet piles was designed for the town end of the bridge. The sheet piles contained 0.2 % Cu. A 12" utility water line will be attached to the outside of the barrier rail.

Observations and Points of Discussion:

  • Bent caps appeared unusually deep.
  • There were questions about the development of 'S' bars in the Texas rail.
  • The geometry of the intersection at the end of the bridge opposite from the town raised several issues including:
    • Sight distances at the landing of the two bridges
      Difficulties of shop curving wrap-around guardrail.
      Difficulties in forming the curved decorative Texas barrier rail so that it could tie into the guardrail.
  • Some box beam units appeared to have excessive sweep.
    • Emphasized the need to ensure yard fit-up and match marking the box beam units.
  • Order of placing box beam units can influence the size of the gap between units:
    • Placing the center unit and then placing adjacent units working to the exterior units, or
      Placing one exterior unit and then placing adjacent units up to the opposite exterior unit.
  • Consider eliminating retainer blocks since dowels act as lateral movement restraints.


picture 1 picture 2 picture 3 picture 4 picture 5 picture 6 picture 7
 
picture 8 picture 9 picture 10 picture 11 picture 12 picture 13 picture 14
 
picture 15 picture 16 picture 17 picture 18 picture 19 picture 20 picture 21
 
picture 22 picture 23 picture 24 picture 25 picture 26 picture 27 picture 28
 
picture 29 picture 30 picture 31 picture 32 picture 33 picture 34 picture 35
 
picture 36 picture 37 picture 38 picture 39 picture 40 picture 41 picture 42
 
picture 43 picture 44 picture 45 picture 46 picture 47 picture 48 picture 49



spacer spacer
spacer
 
North Carolina DOT Logo   The North Carolina
Department of Transportation